<LOGO>
FM Transmitter Measurement Report
Created: 2024-03-05 11-33-02
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 42 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
7 kHz 41 kHz 18890 0,2223
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,2 dBr -0,52 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 11:32, 5.03.2024
RT
"Cesky ro "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 41 kHz MIN: 7 kHz % above 77 kHz: 0,2223 Acquired: 2024/03/05 11:32:59 Total samples: 18890 Equivalent time: 0:15:44 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 0,0 dBr MIN: -1,2 dBr AVE: -0,52 dBr % above 0,2 dBr: 0,0 Last value: -1,1 dBr (2024/03/05 11:32:59) 11:20 11:22 11:24 11:26 11:28 11:30 11:32 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality